(D). Notes

  1. Rinse with 5% dilute sulphuric acid for activation before rhodium plating, then D.I. rinse.
  2. Nickel, gold or palladium nickel plate before rhodium plating is recommended for better result.
  3. Low rhodium content, low temperature and high acid content will slow down deposition rate.
  4. Avoid metallic contamination, use RHP-20 purifier when necessary to remove them.
  5. Keep rhodium content within 10% range.
  6. Low acid RD-A1 will not cause acid build-up, acid attack on anode is avoided.
  7. Carbon filter cartridge should be used constantly to avoid organic contamination.
  8. 1g/l rhodium is preferred when first make-up.
  9. Rhodstar RD-A1 is highly compatible to most of common brand rhodium solution.
  10. High grade sulphuric acid must be used in the Rh bath and acid rinse bath.
  11. New plating equipment must be thoroughly cleaned before use.
  12. Avoid partial overheating
  13. Please wear mask, gloves, goggles to handle AS-1 and conc. sulphuric acid.